cmcouwenbLV1Offline
Following: 0Followers: 0
Forums/ Controllers
2021-09-07 12:53:08
Re:WPA Authentication Timeout/Failure after last firmware 1.1.1 upgrade TL-R605 V1.0
@Fae Upgrade to latest version of TL-SG2008 firmware was successful after first upgrade to 20210407 release. Authentication problem is solved with this release! And in the captured traffic I see no...
0HELPFULS
Forums/ Controllers
2021-09-06 21:37:48
Re:WPA Authentication Timeout/Failure after last firmware 1.1.1 upgrade TL-R605 V1.0
@Fae I have tried the upgrade to the new firmware, but I got an error in which it says upgrade failed incompatible file. It could be that I first have to upgrade to build 20210407 and then to...
0HELPFULS
Forums/ Controllers
2021-09-06 07:05:01
Re:WPA Authentication Timeout/Failure after last firmware 1.1.1 upgrade TL-R605 V1.0
@Somnus Hi, I have captured the traffic from EAP to the Radius server. The result is that there is a problem with the firmware of the switch TL-SG2008 V3.0 build 20210407 When the communication...
0HELPFULS
Forums/ Controllers
2021-09-02 22:14:05
Re:WPA Authentication Timeout/Failure after last firmware 1.1.1 upgrade TL-R605 V1.0
@Somnus Sometimes authentication failure is related to network environment. Is there any new interference in your network environment? There is no new interference possible because I am experiencing...
0HELPFULS
Forums/ Controllers
2021-09-01 15:31:03
WPA Authentication Timeout/Failure after last firmware 1.1.1 upgrade TL-R605 V1.0
We are currently experiencing problems with realizing a WiFi connection. The authentication for a WiFi connection is done via WPA-Enterprise and the RADIUS profile server is Windows NPS. This is the...
0HELPFULS
Forums/ Controllers
2021-02-08 14:44:24
Omada log "detected Ping of Death" useless information
@development TP-LINK The Omada SDN controller log's a warning which states that is has taken an action against a possible attack. But it does not log which address is causing this attack. So, I am...
3HELPFULS